Festo CiA 402 Manual page 87

For motor controller
Table of Contents

Advertisement

4
Setting parameters
Bit
Value
Name
0
0001
actual_position_at_homing Actual position is changed at homing (-32767).
h
1
0002
reserved
h
2
0004
homing_method_scheme
h
3
0008
emergency_over_cob_par
h
4
0010
response_after_save
h
5
0020
reserved
h
6
0040
reserved
h
7
0080
device_control
h
8
0100
reserved
h
Festo – GDCP-CMMS/D-C-CO-EN – 1404NH – English
Description
The bit is reserved. It must not be set.
Default, fixed at 1. If this bit is set, the homing
methods 32 ... 35 are numbered in accordance with
CiA 402.
EMCY ID can either be generated automatically or
parameterised via COB_ID used.
Default: 0 = EMCY ID = 80h + node ID
Default, fixed = 1. If this bit is set, the answer to
save_all_parameters is not sent until saving is
completed. This can take several seconds, which
might result in a time-out in the controller. If the bit is
deleted, the answer is issued immediately. However,
it should be considered that the saving procedure has
not been completed yet.
The bit is reserved. It must not be set.
The bit is reserved. It must not be set.
Default, fixed = 1. If this bit is set, bit 4 of the
statusword (voltage_enabled) is output in accordance
with CiA 402 v2.0. In addition, the status
FAULT_REACTION_ACTIVE is distinguishable from the
FAULT status (
Chapter 5).
The bit is reserved. It must not be set.
87