Advertisement

4
Setting parameters
4.4

Current Regulator and Motor Adjustment

Caution
Incorrect settings of the current regulator parameters and current limits can destroy the
motor and, possibly, also the motor controller within a very short time!
Overview
The parameter set of the motor controller must be adapted for the connected motor.
Caution
If the phase sequence is distorted in the motor or angle encoder cable, the result may
be positive feedback, so the speed in the motor cannot be regulated. The motor can
turn uncontrollably!
Description of the Objects
Index
Object
6075
VAR
h
6073
VAR
h
604D
VAR
h
6410
RECORD
h
60F6
RECORD
h
Affected objects from other chapters
Index
Object
2415
RECORD
h
Object 6075
: motor_rated_current
h
This value can be taken from the motor rating plate and is entered in milliamperes. The effective value
(RMS) is always assumed. No current can be specified above the motor controller nominal current.
Index
Name
Object Code
Data Type
Access
PDO Mapping
Units
Value Range
Default Value
If the object 6075
6073
(max_current) must always be parametrised again.
h
62
Name
motor_rated_current
max_current
pole_number
motor_data
torque_control_parameters
Name
current_limitation
6075
h
motor_rated_current
VAR
UINT32
rw
yes
ma
0 ... nominal_current (motor controller nominal current, see technical data)
1499
(motor_rated_current) is written over with a new value, the object
h
Type
UINT32
UINT16
UINT8
Type Chapter
4.7 Setpoint value limitation
Festo – GDCP-CMMS/D-C-CO-EN – 1404NH – English
Attr.
rw
rw
rw
rw
rw