Avaya X330W2-DS1 User Manual page 163

Multiservice wan access router module
Hide thumbs Also See for X330W2-DS1:
Table of Contents

Advertisement

The following are the show controllers command output fields:
Field
T1 1 is down
Cablelength
Remote alarm
Framing
Line Code
Clock Source
Channel
Group
Data in current
interval
(347 seconds
elapsed)
Line Code
Violations
Avaya X330W-2DS1 User's Guide
Description
Displays that the T1 controller 1 is not operating. The
controller's state can be: up, down, or administratively down.
Loopback conditions are shown either as being locally looped
or remotely looped.
Displays the current line buildout. Relevant for T1 lines only.
Any alarms detected by the controller are displayed. The
possible alarms are:
• Transmitter is sending remote alarm.
• Transmitter is sending alarm indication signal (AIS).
• Receiver has loss of signal.
• Receiver is getting AIS.
• Receiver has loss of frame.
• Receiver has remote alarm.
• Receiver has no alarms.
• Receiver has major alarm.
Shows the current framing type. The default framing type for
E1 is CRC4. The default framing type for T1 is SF.
Displays the current line code. The default line code for E1 is
HDB3. The default line code for T1 is AMI.
Displays the current clock source. The possible clock sources
are either Line or Internal.
Displays the channel group number and timeslots.
Displays the current accumulation period (from 1-900 seconds),
which rolls into a 24 hour accumulation every 15 minutes. The
oldest 15 minute period falls off the back of the 24 hour
accumulation buffer.
Displays either no line code violations, the occurrence of a
Bipolar Violation, or the occurrence of an Excessive Zeros error
event.
WAN CLI Commands
141

Advertisement

Table of Contents
loading

Table of Contents