CleaverBrooks CFC-500 Operation, Service And Parts Manual page 80

Clearfire condensing boiler
Hide thumbs Also See for CFC-500:
Table of Contents

Advertisement

Section 4 — CFC Commissioning
Parameter Group
Parameter Name
Pump Configuration
Boiler pump options 2
Pump Configuration
System pump options 1
Pump Configuration
System pump options 2
Auxiliary 1 pump overrun
Pump Configuration
time
Pump Configuration
Auxiliary 1 pump options 1
Pump Configuration
Auxiliary 1 pump options 2
Pump Configuration
Auxiliary 2 pump output
Pump Configuration
Auxiliary 2 pump control
Pump Configuration
Auxiliary 2 pump start delay
Auxiliary 2 pump overrun
Pump Configuration
time
Pump Configuration
Auxiliary 2 pump options 1
Pump Configuration
Auxiliary 2 pump options 2
Statistics Configuration
Burner cycle count
Statistics Configuration
Burner run time
Statistics Configuration
CH pump cycle count
Statistics Configuration
DHW pump cycle count
Statistics Configuration
System pump cycle count
Statistics Configuration
Boiler pump cycle count
Statistics Configuration
Auxiliary 1 pump cycle count Read Only
Statistics Configuration
Auxiliary 2 pump cycle count Read Only
System Configuration
Temperature units
System Configuration
Antishort cycle time
System Configuration
Alarm silence time
System Configuration
Power-up with lockout
System Configuration
Burner switch
System Configuration
Blower/HSI function
System Configuration
Flame sensor type
System Configuration
Forced recycle interval time
System Configuration
Fan speed error response
System (Sensor) Configuration
Inlet sensor type
S2 (remote 4-20mA or
System (Sensor) Configuration
header) sensor type
System (Sensor) Configuration
Outlet sensor type
System (Sensor) Configuration
S5 (outdoor) sensor type
System (Sensor) Configuration
DHW sensor type
System (Sensor) Configuration
Stack sensor type
System (Sensor) Configuration
Outdoor temperature source
Warm weather shutdown
System Configuration
enable
Warm weather shutdown
System Configuration
setpoint
Use STAT with EnviraCOM
System Configuration
remote stat
Fan Configuration
Absolute max. fan speed
Fan Configuration
Absolute min. fan speed
Fan Configuration
PWM frequency
Fan Configuration
Pulses per revolution
4-10
Table 4-1 CFC default parameter settings
Min.
Access*
Range
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Service
Service
Service
Read Only
User
Read Only
OEM
Service
Service
Read Only
OEM
Read Only
Service
Service
Service
Service
Service
Service
Hidden
OEM
2000
OEM
800
OEM
1000
Read Only
Max.
Default Setting
Range
0xC0DF
0xE36C
0x801D
0
300
28800
0x0003
0x4002
Pump C
Auto
0
0
28800
0
0
28800
0x0000
0x4001
0
999,999
0
999,999
0
999,999
0
999,999
0
999,999
0
999,999
0
999,999
0
999,999
Fahrenheit
0
60
28800
0
0
3600
Do NOT clear lockout
Off
Blower
Flame rod
0
Lockout
10k NTC single non-
safety
4-20mA
10k NTC dual safety
10k NTC single non-
safety
10k NTC single non-
safety
Unconfigured
Unconfigured
Warm weather
shutdown disabled
100
Disable
6000
6500
800
3000
3000
4000
2
3
3
Parameter
Units
Installation Setting
seconds
seconds
seconds
seconds
seconds
seconds
°F
RPM
RPM
Hz
Part No. 750-263
Modbus
Register
(dec)
0301
0302
0303
0752
0753
0754
0755
0756
0757
0758
0759
0760
0128
0130
0132
0134
0136
0138
0140
0146
0178
0179
0180
0181
0203
0225
0228
0254
0255
608
609
610
611
612
613
626
0627
0628
0629
0256
0257
0258
0259