CleaverBrooks CFC-500 Operation, Service And Parts Manual page 83

Clearfire condensing boiler
Hide thumbs Also See for CFC-500:
Table of Contents

Advertisement

Parameter Group
Parameter Name
CH anti-condensation pump
Anti-condensation Configuration
force off
DHW anti-condensation
Anti-condensation Configuration
enable
DHW anti-condensation
Anti-condensation Configuration
setpoint
DHW anti-condensation
Anti-condensation Configuration
pump force off
Anti-condensation > Outlet
Anti-condensation Configuration
limit
Anti-condensation Configuration Anti-condensation > Delta-T
Anti-condensation > Stack
Anti-condensation Configuration
limit
Anti-condensation > Slow
Anti-condensation Configuration
start
Anti-condensation > Forced
Anti-condensation Configuration
rate
Frost protect
Anti-condensation Configuration
anticondensation enable
Frost Protection Configuration
CH frost protection enable
Frost Protection Configuration
DHW frost protection enable
Outdoor frost protection
Frost Protection Configuration
setpoint
Frost Protection Configuration
LL frost protection enable
Frost Protection Configuration
LL frost protection rate
Lead Lag Configuration
Lead Lag slave enable
Lead Lag Configuration
Lead Lag master enable
Lead Lag Configuration
Lead Lag CH setpoint
Lead Lag Configuration
Lead Lag CH TOD setpoint
Lead Lag Configuration
Lead Lag on hysteresis
Lead Lag Configuration
Lead Lag off hysteresis
Lead Lag hysteresis step
Lead Lag Configuration
time
Lead Lag Configuration
Lead Lag P gain
Lead Lag Configuration
Lead Lag I gain
Lead Lag Configuration
Lead Lag D gain
Lead Lag Configuration
Lead Lag operation switch
Lead Lag Configuration
Lead Lag CH demand switch
Lead Lag Configuration
Lead Lag CH setpoint source
Lead Lag modulation backup
Lead Lag Configuration
sensor
Lead Lag CH 4mA water
Lead Lag Configuration
temperature
Lead Lag CH 20mA water
Lead Lag Configuration
temperature
Lead Lag Configuration
Slave mode
Lead Lag Configuration
Base load rate
Lead Lag Configuration
Fan rate during off cycle
Lead Lag Configuration
Slave sequence order
Lead Lag Configuration
Lead Lag Modbus port
Lead Lag slave demand to
Lead Lag Configuration
firing delay
Lead Lag Configuration
Base load common
Lead Lag Configuration
Lead selection method
Lead Lag Configuration
Lag selection method
Lead Lag add stage method
Lead Lag Configuration
1
Part No. 750-263
Table 4-1 CFC default parameter settings
Min.
Access*
Range
Service
Service
Service
32
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
-40
Service
Service
Service
Service
Service
32
Service
32
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
800
Service
Service
Service
Service
60
Service
Service
Service
Service
Max.
Default Setting
Range
Disabled
Disabled
140
194
Disabled
No
No
No
Yes
Yes
No
Disabled
Disabled
32
120
Disabled
0
20%
100
Disabled
Disabled
150
230
120
230
5
15
60
0
10
400
0
25
400
0
0
400
Yes/True/On
STAT terminal
Local
Use average of all
slave outlet sensors
80
180
Equalize run time
2000
6000
0
0
6000
0
MB2
300
0
45%
100
Lowest measured run
time
Rotate in sequence
order
Firing rate threshold
Section 4 — CFC Commissioning
Parameter
Units
Installation Setting
°F
°F
°F
°F
°F
°F
seconds
°F
°F
RPM
RPM
seconds
%
Modbus
Register
(dec)
0498
0499
0500
0501
0502
0502
0502
0502
0502
0503
0528
0529
0530
0532
0533
0544
0545
0546
0547
0549
0550
0551
0552
0553
0554
0555
0556
0557
0559
0560
0561
0564
0566
0567
0568
0569
0570
0572
0574
0575
0714
4-13