CleaverBrooks CFC-500 Operation, Service And Parts Manual page 236

Clearfire condensing boiler
Hide thumbs Also See for CFC-500:
Table of Contents

Advertisement

CB FALCON
Code
194
Invalid ignite failure response setting
195
Invalid ignite failure retries setting
196
Invalid ignition source setting
197
Invalid interlock open response setting
198
Invalid interlock start check setting
199
Invalid LCI enable setting
200
Invalid lightoff rate setting
201
Invalid lightoff rate proving setting
202
Invalid Main Flame Establishing Period time
203
Invalid MFEP flame failure response setting
204
Invalid NTC sensor type setting
205
Invalid Outlet high limit response setting
206
Invalid Pilot Flame Establishing Period
setting
207
Invalid PII enable setting
208
Invalid pilot test hold setting
209
Invalid Pilot type setting
210
Invalid Postpurge time setting
211
Invalid Power up with lockout setting
212
Invalid Preignition time setting
213
Invalid Prepurge rate setting
214
Invalid Prepurge time setting
215
Invalid Purge rate proving setting
216
Invalid Run flame failure response setting
217
Invalid Run stabilization time setting
218
Invalid Stack limit enable setting
219
Invalid Stack limit response setting
220
Unconfigured Delta T limit setpoint setting
221
Unconfigured DHW high limit setpoint
setting
222
Unconfigured Outlet high limit setpoint
setting
223
Unconfigured Stack limit setpoint setting
224
Invalid DHW demand source setting
225
Invalid Flame threshold setting
226
Invalid Outlet high limit setpoint setting
227
Invalid DHW high limit setpoint setting
228
Invalid Stack limit setpoint setting
229
Invalid Modulation output setting
230
Invalid CH demand source setting
231
Invalid Delta T limit delay setting
232
Invalid Pressure sensor type setting
233
Invalid IAS closed response setting
234
Invalid Outlet high limit enable setting
235
Invalid Outlet connector type setting
236
Invalid Inlet connector type setting
237
Invalid DHW connector type setting
238
Invalid Stack connector type setting
750-265
Table 49. Falcon Lockout and Hold Codes. (Continued)
Description
Recommended Troubleshooting of Lockout Codes
1. Return to Configuration mode and recheck selected
parameters, reverify and reset module.
2. If fault repeats, verify electrical grounding.
3. If fault repeats, replace module.
112
NOTE
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cfc-2500Cfc-750Cfc-1000Cfc-1500Cfc-1800

Table of Contents