CleaverBrooks CFC-500 Operation, Service And Parts Manual page 240

Clearfire condensing boiler
Hide thumbs Also See for CFC-500:
Table of Contents

Advertisement

CB FALCON
Table 50. Alerts. (Continued)
Code
209
Too many Lead Lag slaves were detected
210
Lead Lag slave was discovered
211
Incompatible Lead Lag slave was discovered
212
No base load rate was set for Lead Lag slave
213
Lead Lag slave unable to fire before demand to
214
Adding Lead Lag slave aborted due to add
215
No Lead Lag slaves available to service demand
216
No Lead Lag active service was set due to
217
No Lead Lag add stage method was specified
218
No Lead Lag drop stage method was specified
219
Using backup lead lag header sensor due to
Frost Protection Faults
220
Lead Lag frost protection rate was invalid
221
Lead Lag drop stage method setting was invalid
222
CH frost protection temperature was invalid
223
CH frost protection inlet temperature was invalid
224
DHW frost protection temperature was invalid
225-226
RESERVED
227
DHW priority override time was not derated due
228
Warm weather shutdown was not checked due
229
Lead Lag slave communication timeout
230
RESERVED
231
Lead Lag CH setpoint was invalid
232
Lead Lag CH time of day setpoint was invalid
233
LL outdoor temperature was invalid
234
Lead Lag ODR time of day setpoint was invalid
235
Lead Lag ODR time of day setpoint exceeded
236
Lead Lag ODR max outdoor temperature was
237
Lead Lag ODR min outdoor temperature was
238
Lead Lag ODR low water temperature was
239
Lead Lag ODR outdoor temperature range was
240
Lead Lag ODR water temperature range was too
241
Lead Lag DHW setpoint was invalid
242
Lead Lag Mix setpoint was invalid
243
Lead Lag CH demand switch was invalid
244
Lead Lag CH setpoint source was invalid
245
RESERVED
246
CH setpoint was invalid
247
CH time of day setpoint was invalid
248
CH outdoor temperature was invalid
249
CH ODR time of day setpoint was invalid
250
CH ODR time of day setpoint exceeds normal
251
CH max outdoor setpoint was invalid
750-265
Description
Table 50. Alerts. (Continued)
Code
252
CH min outdoor setpoint was invalid
253
CH min water setpoint was invalid
254
CH outdoor temperature range was too small
255
CH water temperature range was too small
256
Steam setpoint was invalid
257
Steam time of day setpoint was invalid
258
Steam minimum pressure was invalid
259
CH ODR min water temperature was invalid
260
RESERVED
261
DHW setpoint was invalid
262
DHW time of day setpoint was invalid
263
DHW storage setpoint was invalid
264
STAT may not be a DHW demand source when
265-266
RESERVED
267
STAT may not be a CH demand source when
268
CH 4mA water temperature setting was invalid
269
CH 20mA water temperature setting was invalid
270
Steam 4mA water temperature setting was
271
Steam 20mA water temperature setting was
272
Abnormal Recycle: Pressure sensor fault
273
Abnormal Recycle: Safety relay drive test failed
274
Abnormal Recycle: Demand off during Pilot
275
Abnormal Recycle: LCI off during Drive to Purge
276
Abnormal Recycle: LCI off during Measured
277
Abnormal Recycle: LCI off during Drive to
278
Abnormal Recycle: LCI off during Pre-Ignition
279
Abnormal Recycle: LCI off during Pre-Ignition
280
Abnormal Recycle: LCI off during Main Flame
281
Abnormal Recycle: LCI off during Ignition period
282
Abnormal Recycle: Demand off during Drive to
283
Abnormal Recycle: Demand off during Measured
284
Abnormal Recycle: Demand off during Drive to
285
Abnormal Recycle: Demand off during Pre-
286
Abnormal Recycle: Demand off during Pre-
287
Abnormal Recycle: Flame was on during Safe
288
Abnormal Recycle: Flame was on during Drive to
289
Abnormal Recycle: Flame was on during
290
Abnormal Recycle: Flame was on during Drive to
291
Abnormal Recycle: Flame was not on at end of
292
Abnormal Recycle: Flame was lost during Main
293
Abnormal Recycle: Flame was lost early in Run
294
Abnormal Recycle: Flame was lost during Run
295
Abnormal Recycle: Leakage test failed
116
Description

Hide quick links: