CleaverBrooks CFC-500 Operation, Service And Parts Manual page 242

Clearfire condensing boiler
Hide thumbs Also See for CFC-500:
Table of Contents

Advertisement

CB FALCON
Table 50. Alerts. (Continued)
Code
381
Abnormal Recycle: Fan Speed Range Low
382
Abnormal Recycle: Fan Speed Range High
383-450
RESERVED
Circulator Errors
451
Circulator control was invalid
452
Circulator P-gain was invalid
453
Circulator I-gain was invalid
454
Circulator temperature was invalid
455
Circulator outlet temperature was invalid
456
Circulator inlet temperature was invalid
457
Circulator outdoor temperature was invalid
458
Circulator sensor choice was invalid
459
Circulator PID setpoint was invalid
Debug Faults
460
LCI lost in run
461
Abnormal Recycle: Demand lost in run from
462
Abnormal Recycle: Demand lost in run due to
463
Abnormal Recycle: Demand lost in run due to no
464
LCI lost in Combustion Pressure Establishing
465
LCI lost in Combustion Pressure Stabilization
466
RESERVED
Internal Data Faults
467
Internal error: EEPROM write was attempted
468
Internal error: EEPROM cycle count address
469
Internal error: EEPROM days count address was
470
Internal error: EEPROM hours count address
471
Internal error: Lockout record EEPROM index
472
Internal error: Request to write PM status was
473
Internal error: PM parameter address was invalid
474
Internal error: PM safety parameter address was
475
Internal error: Invalid record in lockout history
476
Internal error: EEPROM write buffer was full
477
Internal error: Data too large was not written to
478
Internal error: Safety key bit 0 was incorrect
479
Internal error: Safety key bit 1 was incorrect
480
Internal error: Safety key bit 2 was incorrect
481
Internal error: Safety key bit 3 was incorrect
482
Internal error: Safety key bit 4 was incorrect
483
Internal error: Safety key bit 5 was incorrect
484
Internal error: Safety key bit 6 was incorrect
485
Internal error: Safety key bit 7 was incorrect
486
Internal error: Safety key bit 8 was incorrect
487
Internal error: Safety key bit 9 was incorrect
750-265
Description
Table 50. Alerts. (Continued)
Code
488
Internal error: Safety key bit 10 was incorrect
489
Internal error: Safety key bit 11 was incorrect
490
Internal error: Safety key bit 12 was incorrect
491
Internal error: Safety key bit 13 was incorrect
492
Internal error: Safety key bit 14 was incorrect
493
Internal error: Safety key bit 15 was incorrect
494
Internal error: Safety relay timeout
495
Internal error: Safety relay commanded off
496
Internal error: Unknown safety error occurred
497
Internal error: Safety timer was corrupt
498
Internal error: Safety timer was expired
499
Internal error: Safety timings
500
Internal error: Safety shutdown
501
RESERVED
MIX Errors
502
Mix setpoint was invalid
503
Mix time of day setpoint was invalid
504
Mix outdoor temperature was invalid
505
Mix ODR time of day setpoint was invalid
506
Mix ODR time of day setpoint exceeds normal
setpoint
507
Mix ODR max outdoor temperature was invalid
508
Mix ODR min outdoor temperature was invalid
509
Mix ODR low water temperature was invalid
510
Mix ODR outdoor temperature range was invalid
511
Mix ODR water temperature range was invalid
512
Mix demand switch was invalid
513
Mix ON hysteresis was invalid
514
Mix OFF hysteresis was invalid
515
Mix ODR min water temperature was invalid
516
Mix hysteresis step time was invalid
517
Mix P-gain was invalid
518
Mix I-gain was invalid
519
Mix D-gain was invalid
520
Mix control was suspended due to fault
521
Mix S10 (J10-7) temperature was invalid
522
Mix outlet temperature was invalid
523
Mix inlet temperature was invalid
524
Mix S5 (J8-11) temperature was invalid
525
Mix modulation sensor type was invalid
526
Mix ODR min water temperature setpoint was
invalid
527
Mix circulator sensor was invalid
528
Mix flow control was invalid
529
Mix temperature was invalid
530
Mix sensor was invalid
118
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cfc-2500Cfc-750Cfc-1000Cfc-1500Cfc-1800

Table of Contents