Table 48. Example of a Completed Device Parameter Worksheet. (Continued)
Parameter Name
Annunciator 4 location
Annunciator4 short name
Annunciator 4 long name
Annunciator 5 location
Annunciator5 short name
Annunciator 5 long name
Annunciator 6 location
Annunciator6 short name
Annunciator 6 long name
Annunciator 7 location
Annunciator7 short name
Annunciator 7 long name
Annunciator 8 location
Annunciator8 short name
Annunciator 8 long name
PII short name
PII long name
LCI short name
LCI long name
ILK short name
ILK long name
DHW enable
DHW demand source
DHW has priority over CH
DHW has priority over LL
DHW priority time
DHW setpoint
DHW tod setpoint
DHW on hysteresis
DHW off hysteresis
DHW P gain
DHW I gain
DHW D gain
DHW hysteresis step time
Outlet high limit setpoint
Outlet high limit response
Stack limit enable
Stack limit setpoint
Stack limit response
Customer
Choice - Hidden,
Read Only or
Password
protected
Minimum Range
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
32°F 0°C
Read Only
32°F 0°C
Read Only
2°F 1°C
Read Only
2°F 1°C
Read Only
0
Read Only
0
Read Only
0
Read Only
Read Only
32°F 0°C
Read Only
[ A B #c #d ]
Read Only
Read Only
32°F 0°C
Read Only
[ A #b C #d ]
Default Setting
A:No annunciation
for this terminal
A4
Annunciator4
E:No annunciation
for this terminal
A5
Annunciator5
E:No annunciation
for this terminal
A6
Annunciator6
E:No annunciation
for this terminal
A7
Annunciator7
E:No annunciation
for this terminal
A8
Annunciator8
PII
Pre-Ignition ILK
LCI
Load Control Input
ILK
Interlock
Disabled
A:DHW sensor
only
No/False/Off
No/False/Off
30m 0s
140°F 60°C
240°F 116°C
120°F 49°C
240°F 116°C
5°F 3°C
100°F 56°C
5°F 3°C
100°F 56°C
50
400
50
400
50
400
0m 0s
220°F 104°C
240°F 116°C
A:Lockout
Disabled
200°F 93°C
500°F 260°C
A:Lockout
103
CB FALCON
Maximum Range Parameter Units
3 chars
20 chars
3 chars
20 chars
3 chars
20 chars
3 chars
20 chars
3 chars
20 chars
3 chars
20 chars
3 chars
20 chars
3 chars
20 chars
mmm:ss
mmm:ss
750-265