Section 4 — CFC Commissioning
Parameter Group
Parameter Name
Plate HX Preheat
Plate preheat OFF hysteresis
Plate preheat minimum on
Plate HX Preheat
time
Tap detect degrees per
Plate HX Preheat
second
Plate HX Preheat
Tap detect ON hysteresis
Tap detect on recognition
Plate HX Preheat
time
Plate HX Preheat
Tap stop Inlet-DHW degrees
Tap stop Outlet-DHW
Plate HX Preheat
degrees
Plate HX Preheat
Tap detect minimum on time
Plate HX Preheat
Tap detect on threshold
Plate preheat detect on
Plate HX Preheat
threshold
Plate preheat detect off
Plate HX Preheat
threshold
Annunciation Configuration
Annunciation enable
Annunciation Configuration
Annunciator 1 location
Annunciation Configuration
Annunciator 1 short name
Annunciation Configuration
Annunciator 1 long name
Annunciation Configuration
Annunciator 2 location
Annunciation Configuration
Annunciator 2 short name
Annunciation Configuration
Annunciator 2 long name
Annunciation Configuration
Annunciator 3 location
Annunciation Configuration
Annunciator 3 short name
Annunciation Configuration
Annunciator 3 long name
Annunciation Configuration
Annunciator 4 location
Annunciation Configuration
Annunciator 4 short name
Annunciation Configuration
Annunciator 4 long name
Annunciation Configuration
Annunciator 5 location
Annunciation Configuration
Annunciator 5 short name
Annunciation Configuration
Annunciator 5 long name
Annunciation Configuration
Annunciator 6 location
Annunciation Configuration
Annunciator 6 short name
Annunciation Configuration
Annunciator 6 long name
Annunciation Configuration
Annunciator 7 location
Annunciation Configuration
Annunciator 7 short name
Annunciation Configuration
Annunciator 7 long name
Annunciation Configuration
Annunciator 8 location
Annunciation Configuration
Annunciator 8 short name
Annunciation Configuration
Annunciator 8 long name
Annunciation Configuration
PII short name
Annunciation Configuration
PII long name
Annunciation Configuration
LCI short name
Annunciation Configuration
LCI long name
Annunciation Configuration
ILK short name
Annunciation Configuration
ILK long name
Anti-condensation Configuration CH anti-condensation enable
CH anti-condensation
Anti-condensation Configuration
setpoint
4-12
Table 4-1 CFC default parameter settings
Min.
Access*
Range
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Hidden
OEM
OEM
OEM
Service
Service
Service
OEM
OEM
OEM
OEM
OEM
OEM
OEM
OEM
OEM
OEM
OEM
OEM
Service
Service
Service
Service
Service
Service
OEM
OEM
OEM
OEM
OEM
OEM
Service
Service
32
Max.
Default Setting
Range
5
60
2
20
5
5
10
60
No value
No value
No value
Enabled
Other
A1
AIR SWITCH
Unused (or LCI)
A2
AUX LOW WATER
ILK
A3
LOW WATER
ILK
A4
HIGH AIR PRESSURE
ILK
A5
HIGH GAS
PRESSURE
ILK
A6
LOW GAS PRESSURE
ILK
A7
NATURAL GAS
ILK
A8
LP GAS
PII
Pre-Ignition ILK
LCI
Load Control Input
ILK
Interlock
Disabled
140
194
Parameter
Units
Installation Setting
°F
not used
seconds
not used
°F
not used
°F
not used
seconds
not used
°F
not used
°F
not used
seconds
not used
°F
not used
°F
not used
°F
not used
°F
Part No. 750-263
Modbus
Register
(dec)
0692
0693
0694
0695
0696
0697
0698
0699
0700
0701
0702
0304
0306
0307
0309
0319
0320
0322
0332
0333
0335
0345
0346
0348
0358
0359
0361
0371
0372
0374
0384
0385
0387
0397
0398
0400
0410
0412
0422
0424
0434
0436
0496
0497