CB FALCON MODBUS COMMUNICATION
Table 10. Falcon alert codes
257
Steam time of day setpoint was invalid
258
Steam minimum pressure was invalid
259
CH ODR min water temperature was invalid
260
RESERVED
261
DHW setpoint was invalid
262
DHW time of day setpoint was invalid
263
DHW storage setpoint was invalid
264
STAT may not be a DHW demand source when
Remote Stat is enabled
265-266 RESERVED
267
STAT may not be a CH demand source when
Remote Stat is enabled
268
CH 4mA water temperature setting was invalid
269
CH 20mA water temperature setting was invalid
270
Steam 4mA water temperature setting was invalid
271
Steam 20mA water temperature setting was invalid
272
Abnormal Recycle: Pressure sensor fault
273
Abnormal Recycle: Safety relay drive test failed
274
Abnormal Recycle: Demand off during Pilot Flame
Establishing Period
275
Abnormal Recycle: LCI off during Drive to Purge
Rate
276
Abnormal Recycle: LCI off during Measured Purge
Time
277
Abnormal Recycle: LCI off during Drive to Lightoff
Rate
278
Abnormal Recycle: LCI off during Pre-Ignition test
279
Abnormal Recycle: LCI off during Pre-Ignition time
280
Abnormal Recycle: LCI off during Main Flame
Establishing Period
281
Abnormal Recycle: LCI off during Ignition period
282
Abnormal Recycle: Demand off during Drive to
Purge Rate
283
Abnormal Recycle: Demand off during Measured
Purge Time
284
Abnormal Recycle: Demand off during Drive to
Lightoff Rate
285
Abnormal Recycle: Demand off during Pre-Ignition
test
286
Abnormal Recycle: Demand off during Pre-Ignition
time
287
Abnormal Recycle: Flame was on during Safe Start
check
288
Abnormal Recycle: Flame was on during Drive to
Purge Rate
289
Abnormal Recycle: Flame was on during Measured
Purge Time
290
Abnormal Recycle: Flame was on during Drive to
Lightoff Rate
291
Abnormal Recycle: Flame was not on at end of
Ignition period
292
Abnormal Recycle: Flame was lost during Main
Flame Establishing Period
Table 10. Falcon alert codes
293
Abnormal Recycle: Flame was lost early in Run
294
Abnormal Recycle: Flame was lost during Run
295
Abnormal Recycle: Leakage test failed
296
Abnormal Recycle: Interrupted air flow switch was
off during Drive to Purge Rate
297
Abnormal Recycle: Interrupted air flow switch was
off during Measured Purge Time
298
Abnormal Recycle: Interrupted air flow switch was
off during Drive to Lightoff Rate
299
Abnormal Recycle: Interrupted air flow switch was
off during Pre-Ignition test
300
Abnormal Recycle: Interrupted air flow switch was
off during Pre-Ignition time
301
Abnormal Recycle: Interrupted air flow switch was
off during Main Flame Establishing Period
302
Abnormal Recycle: Ignition failed due to interrupted
air flow switch was off
303
Abnormal Recycle: ILK off during Drive to Purge
Rate
304
Abnormal Recycle: ILK off during Measured Purge
Time
305
Abnormal Recycle: ILK off during Drive to Lightoff
Rate
306
Abnormal Recycle: ILK off during Pre-Ignition test
307
Abnormal Recycle: ILK off during Pre-Ignition time
308
Abnormal Recycle: ILK off during Main Flame
Establishing Period
309
Abnormal Recycle: ILK off during Ignition period
310
Run was terminated due to ILK was off
311
Run was terminated due to interrupted air flow
switch was off
312
Stuck reset switch
313
Run was terminated due to fan failure
314
Abnormal Recycle: Fan failed during Drive to Purge
Rate
315
Abnormal Recycle: Fan failed during Measured
Purge Time
316
Abnormal Recycle: Fan failed during Drive to
Lightoff Rate
317
Abnormal Recycle: Fan failed during Pre-Ignition
test
318
Abnormal Recycle: Fan failed during Pre-Ignition
time
319
Abnormal Recycle: Fan failed during Ignition period
320
Abnormal Recycle: Fan failed during Main Flame
Establishing Period
321
Abnormal Recycle: Main Valve off after 10 seconds
of RUN
322
Abnormal Recycle: Pilot Valve off after 10 seconds
of RUN
323
Abnormal Recycle: Safety Relay off after 10
seconds of RUN
324
Abnormal Recycle: Hardware flame bias
325
Abnormal Recycle: Hardware static flame