Table 10. Falcon alert codes
164
DHW sensor type was invalid
165
Inlet sensor type was invalid for DHW
166
Outlet sensor type was invalid for DHW
167
DHW storage OFF hysteresis was invalid
168
DHW storage ON hysteresis was invalid
169
DHW modulation sensor type was invalid
170
DHW modulation sensor was not compatible for
Auto mode
171
DHW control was suspended due to fault
172
DHW temperature was invalid
173
DHW inlet temperature was invalid
174
DHW outlet temperature was invalid
175
DHW high limit must be disabled for Auto mode
176
DHW sensor type was not compatible for Auto mode
177
DHW priority source setting was invalid
178
DHW priority method setting was invalid
179
CH S5 (J8-11) sensor was invalid
180
CH Inlet temperature was invalid
181
CH S10 (J10-7) sensor was invalid
182
Lead Lag CH setpoint source was invalid
183
Lead Lag P-gain was invalid
184
Lead Lag I-gain was invalid
185
Lead Lag D-gain was invalid
186
Lead Lag OFF hysteresis was invalid
187
Lead Lag ON hysteresis was invalid
188
Lead Lag slave enable was invalid
189
Lead Lag hysteresis step time was invalid
190
No Lead Lag Modbus port was assigned
191
Lead Lag base load common setting was invalid
192
Lead Lag DHW demand switch setting was invalid
193
Lead Lag Mix demand switch setting was invalid
194
Lead Lag modulation sensor setting was invalid
195
Lead Lag backup modulation sensor setting was
invalid
196
Lead Lag slave mode setting was invalid
197
Lead Lag rate allocation setting was invalid
198
Lead selection setting was invalid
199
Lag selection setting was invalid
200
Lead Lag slave return setting was invalid
201
Lead Lag add stage method setting was invalid
202
STAT may not be a Lead Lag CH demand source
when Remote Stat is enabled
203
Lead Lag base load rate setting was invalid
204
Lead Lag master was suspended due to fault
205
Lead Lag slave was suspended due to fault
206
Lead Lag header temperature was invalid
207
Lead Lag was suspended due to no enabled
Program Module installed
208
Lead Lag slave session has timed out
CB FALCON MODBUS COMMUNICATION
Table 10. Falcon alert codes
209
Too many Lead Lag slaves were detected
210
Lead Lag slave was discovered
211
Incompatible Lead Lag slave was discovered
212
No base load rate was set for Lead Lag slave
213
Lead Lag slave unable to fire before demand to fire
delay expired
214
Adding Lead Lag slave aborted due to add
requirement change
215
No Lead Lag slaves available to service demand
216
No Lead Lag active service was set due to demand
priority conflicts
217
No Lead Lag add stage method was specified
218
No Lead Lag drop stage method was specified
219
RESERVED
220
Lead Lag frost protection rate was invalid
221
Lead Lag drop stage method setting was invalid
222
CH frost protection temperature was invalid
223
CH frost protection inlet temperature was invalid
224
DHW frost protection temperature was invalid
225-230 RESERVED
231
Lead Lag CH setpoint was invalid
232
Lead Lag CH time of day setpoint was invalid
233
Lead Lag outdoor temperature was invalid
234
Lead Lag ODR time of day setpoint was invalid
235
Lead Lag ODR time of day setpoint exceeded
normal setpoint
236
Lead Lag ODR max outdoor temperature was invalid
237
Lead Lag ODR min outdoor temperature was invalid
238
Lead Lag ODR low water temperature was invalid
239
Lead Lag ODR outdoor temperature range was too
small (minimum 12 C / 22 F)
240
Lead Lag ODR water temperature range was too
small (minimum 12 C / 22 F)
241
Lead Lag DHW setpoint was invalid
242
Lead Lag Mix setpoint was invalid
243
Lead Lag CH demand switch was invalid
244
Lead Lag ODR min water temperature was invalid
245
RESERVED
246
CH setpoint was invalid
247
CH time of day setpoint was invalid
248
CH outdoor temperature was invalid
249
CH ODR time of day setpoint was invalid
250
CH ODR time of day setpoint exceeds normal
setpoint
251
CH max outdoor setpoint was invalid
252
CH min outdoor setpoint was invalid
253
CH ODR low water temperature was invalid
254
CH ODR outdoor temperature range was too small
255
CH ODR water temperature range was too small
256
Steam setpoint was invalid
37