Table 10. Falcon alert codes
326
Abnormal Recycle: Hardware flame current invalid
327
Abnormal Recycle: Hardware flame rod short
328
Abnormal Recycle: Hardware invalid power
329
Abnormal Recycle: Hardware invalid AC line
330
Abnormal Recycle: Hardware SLO flame ripple
331
Abnormal Recycle: Hardware SLO flame sample
332
Abnormal Recycle: Hardware SLO flame bias range
333
Abnormal Recycle: Hardware SLO flame bias heat
334
Abnormal Recycle: Hardware SLO spark stuck
335
Abnormal Recycle: Hardware SLO spark changed
336
Abnormal Recycle: Hardware SLO static flame
337
Abnormal Recycle: Hardware SLO rod shorted
338
Abnormal Recycle: Hardware SLO AD linearity
339
Abnormal Recycle: Hardware SLO bias not set
340
Abnormal Recycle: Hardware SLO bias shorted
341
Abnormal Recycle: Hardware SLO electronics
342
Abnormal Recycle: Hardware processor clock
343
Abnormal Recycle: Hardware AC phase
344
Abnormal Recycle: Hardware A2D mismatch
345
Abnormal Recycle: Hardware VSNSR A2D
346
Abnormal Recycle: Hardware 28V A2D
347
Abnormal Recycle: Hardware HFS IAS shorted
348
Abnormal Recycle: Hardware PII INTLK shorted
349
Abnormal Recycle: Hardware HFS LCI shorted
350
Abnormal Recycle: Hardware HFS LFS shorted
351
Abnormal Recycle: Invalid zero crossing
352
Abnormal Recycle: fault stack sensor
353
Abnormal Recycle: stack limit
354
Abnormal Recycle: delta T limit
355
Abnormal Recycle: fault outlet sensor
356
Abnormal Recycle: outlet high limit
357
Abnormal Recycle: fault DHW sensor
358
Abnormal Recycle: DHW high limit
359
Abnormal Recycle: fault inlet sensor
360
Abnormal Recycle: Check Parameters Failed
361
Internal error: No factory parameters were detected
in control
362
Internal error: PID iteration frequency was invalid
363
Internal error: Demand-Rate interval time was
invalid
364
Internal error: Factory calibration parameter for
modulation was invalid
365
Internal error: CH PID P-scaler was invalid
366
Internal error: CH PID I-scaler was invalid
367
Internal error: CH PID D-scaler was invalid
368
Internal error: DHW PID P-scaler was invalid
369
Internal error: DHW PID I-scaler was invalid
370
Internal error: DHW PID D-scaler was invalid
CB FALCON MODBUS COMMUNICATION
Table 10. Falcon alert codes
371
Internal error: Lead Lag master PID P-scaler was
invalid
372
Internal error: Lead Lag master PID I-scaler was
invalid
373
Internal error: Lead Lag master PID D-scaler was
invalid
374
Abnormal Recycle: Hardware flame bias 1
375
Abnormal Recycle: Hardware flame bias 2
376
Abnormal Recycle: Hardware flame bias 3
377
Abnormal Recycle: Hardware flame bias 4
378
Abnormal Recycle: Hardware flame bias 5
379
Abnormal Recycle: Hardware flame bias 6
380-450 RESERVED
451
Circulator control was invalid
452
Circulator P-gain was invalid
453
Circulator I-gain was invalid
454
Circulator temperature was invalid
455
Circulator outlet temperature was invalid
456
Circulator inlet temperature was invalid
457
Circulator outdoor temperature was invalid
458
Circulator sensor choice was invalid
459
Circulator PID setpoint was invalid
460
LCI lost in run
461
Abnormal Recycle: Demand lost in run from
application
462
Abnormal Recycle: Demand lost in run due to high
limit
463
Abnormal Recycle: Demand lost in run due to no
flame
464
LCI lost in Combustion Pressure Establishing Period
465
LCI lost in Combustion Pressure Stabilization Period
466
RESERVED
467
Internal error: EEPROM write was attempted before
EEPROM was initialized
468
Internal error: EEPROM cycle count address was
invalid
469
Internal error: EEPROM days count address was
invalid
470
Internal error: EEPROM hours count address was
invalid
471
Internal error: Lockout record EEPROM index was
invalid
472
Internal error: Request to write PM status was
invalid
473
Internal error: PM parameter address was invalid
474
Internal error: PM safety parameter address was
invalid
475
Internal error: Invalid record in lockout history was
removed
476
Internal error: EEPROM write buffer was full
477
Internal error: Data too large was not written to
EEPROM