CleaverBrooks CFC-500 Operation, Service And Parts Manual page 79

Clearfire condensing boiler
Hide thumbs Also See for CFC-500:
Table of Contents

Advertisement

Parameter Group
Parameter Name
Modulation Configuration
CH max. mod. rate
Modulation Configuration
DHW max. mod. rate
Modulation Configuration
Minimum mod. rate
Modulation Configuration
CH forced rate
Modulation Configuration
CH forced rate time
Modulation Configuration
DHW forced rate
Modulation Configuration
DHW forced rate time
Modulation Configuration
CH slow start enable
Modulation Configuration
DHW slow start enable
Modulation Configuration
Slow start ramp
Modulation Configuration
Slow start setpoint
Modulation Configuration
Analog output hysteresis
Modulation Configuration
Analog input hysteresis
Modulation Configuration
Firing rate control
Modulation Configuration
Manual firing rate
Pump Configuration
CH pump output
Pump Configuration
CH pump control
Pump Configuration
CH pump overrun time
CH pump frost protection
Pump Configuration
overrun time
Pump Configuration
DHW pump output
Pump Configuration
DHW pump control
Pump Configuration
DHW pump overrun time
DHW pump frost protection
Pump Configuration
overrun time
Pump Configuration
DHW pump start delay
Pump Configuration
Boiler pump output
Pump Configuration
Boiler pump control
Pump Configuration
Boiler pump overrun time
Pump Configuration
Auxiliary 1 pump output
Pump Configuration
Auxiliary 1 pump control
Pump Configuration
Auxiliary 1 pump on when
Pump Configuration
System pump output
Pump Configuration
System pump control
Pump Configuration
System pump overrun time
Pump Configuration
Pump exercise interval
Pump Configuration
Pump exercise time
Pump Configuration
CH pump start delay
Pump Configuration
Boiler pump start delay
Pump Configuration
System pump start delay
Pump Configuration
Auxiliary 1 pump start delay
Pump Configuration
CH pump options 1
Pump Configuration
CH pump options 2
Pump Configuration
DHW pump options 1
Pump Configuration
DHW pump options 2
Pump Configuration
Boiler pump options 1
Part No. 750-263
Table 4-1 CFC default parameter settings
Min.
Access*
Range
Service
2000
Service
2000
Service
900
Service
1000
Service
Service
1000
Service
Service
Service
Service
100
Service
Hidden
Service
User
User
900
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Max.
Default Setting
Range
5000
6000
5000
6000
1100
3000
2000
6500
0
0
14400
2000
6500
0
0
14400
Enabled
Disabled
500
5000
0
20
180
0
5
400
0
2
200
Auto
2000
6500
No assignment
Auto
0
300
28800
0
3600
28800
Pump B
Auto
0
60
28800
0
3600
28800
0
0
28800
No assignment
Auto
0
300
28800
Pump A
Auto
Local burner demand
No assignment
Auto
0
900
28800
0
0
28800
0
0
28800
0
0
28800
0
0
28800
0
0
28800
0
0
28800
0XE327
0xC04E
0xE04A
0xC016
0xE30F
Section 4 — CFC Commissioning
Parameter
Units
Installation Setting
RPM
RPM
RPM
RPM
seconds
RPM
seconds
RPM/
minute
deg (below
SP)
steps
(5=0.1 mA)
steps
(1=0.1mA)
RPM
seconds
seconds
seconds
seconds
seconds
seconds
seconds
seconds
seconds
seconds
seconds
seconds
seconds
Modbus
Register
(dec)
0193
0194
0195
0199
0200
0201
0202
0477
0478
0479
0480
0206
0543
0204
0205
0272
0273
0274
0275
0276
0277
0278
0279
0280
0281
0282
0283
0284
0285
0286
0287
0288
0289
0290
0291
0292
0293
0294
0295
0296
0297
0298
0299
0300