11.4 Connector assignment on the PA 110
Power supply see section "PLC power supply"
X2,X3,X4,X5 analogue inputs
Assignment as X15,X16,X17,X18 on PL 410
X7,X8,X9,X10 connection for Pt 100
Assignment as X19,X20,X21,X22 on PL 410
11.5 Connecting cable
Please use only HEIDENHAIN connecting cables.
11.5.1 Connection of PLC inputs/outputs on the LE
HEIDENHAIN recommends the installation of a transfer unit with a terminal strip in the switch
cabinet.
max. 40 m
Id.-Nr. 263 954 ..
If a transfer unit is not required, use HEIDENHAIN connecting cable Id.-Nr. 244 005 ..
Assignment:
1
= green/red
14 = green/blue
2
= brown/black 15 = yellow
3
= white/black
16 = red
4
= green/black
17 = grey
5
= brown/red
18 = blue
6
= white/red
19 = pink
7
= white/green 20 = white/grey
8
= red/blue
21 = yellow/grey
9
= yellow/red
22 = green/red
10 = grey/pink
23 = white/pink
11 = black
24 = grey/green
12 = pink/brown
25 = yellow/brown
13 = yellow/blue
26 = grey/brown
If the connector is to be mounted at the customer's facility, HEIDENHAIN can provide a 37-pin
solderable connector (Id.-Nr. 243 937 ZY).
01.98
TNC 407/TNC 415/TNC 425
27 = yellow/black
28 = white/yellow
29 = grey/blue
30 = pink/blue
31 = pink/red
32 = brown/blue
33 = pink/green
34 = brown
35 = yellow/pink
36 = violet
37 = white
11 PLC inputs/outputs
max. 25 m
Id.-Nr. 244 005..
3-61