11.3.3 PLC inputs/outputs on the PL 400

The PLC inputs/outputs on the PL 400 are spread over nine connectors assigned as follows:
Cables with a core cross-section ≥ dia. 0.14 mm² Cu must be used to connect the PLC inputs and
outputs. Maximum cable length 20 m.
X1
Pin number
Assignment
PL 400 #1
1
O32
2
O33
3
O34
4
O35
5
O36
6
O37
7
O38
8
O39
9
O40
10
O41
11
O42
12
X3
Pin number
Assignment Assignment
PL 400 #1
1
O54
2
O55
2)
3
O56
2)
4
O57
2)
5
O58
2)
6
O59
2)
7
O60
2)
8
O61
2)
9
O62
10
Control ready
11
12
+24 V not interruptible by
ext. EMERGENCY STOP
1)
+24V must always be connected even if the non-interruptible outputs are not used.
2)
Outputs not interruptible by ext. EMERGENCY STOP
01.98
TNC 407/TNC 415/TNC 425
Assignment
PL 400 #2
O64
O65
O66
O67
O68
O69
O70
O71
O72
O73
O74
Do not use
PL 400 #2
O86
O87
2)
O88
2)
O89
2)
O90
2)
O91
2)
O92
2)
O93
2)
O94
Do not use
1)
11 PLC inputs/outputs
X2
Pin number
Assignment Assignment
PL 400 #1
1
O43
2
O44
3
O45
4
O46
5
O47
6
O48
7
O49
8
O50
9
O51
10
O52
11
O53
12
Do not use
X4
Pin number
Assignment Assignment
PL 400 #1
1
I126
2
I74
3
I73
4
I72
5
I71
6
I70
7
I69
8
I68
9
I67
10
I66
11
I65
12
I64
PL 400 #2
O75
O76
O77
O78
O79
O80
O81
O82
O83
O84
O85
PL 400 #2
I254
I202
I201
I200
I199
I198
I197
I196
I195
I194
I193
I192
3-57