16.3.5 Fixing the software limit switch ranges
Determine the software limit switch ranges (see section "Machine axes") as follows:
just before the EMERGENCY STOP limit switches. Note the
16.3.6 Optimizing the control with lag (MP1390 = 1)
The following provisional values can be entered for the machine parameters which determine the
control characteristics:
Machine parameter
MP1050
MP1060
MP1810
MP1820
MP1830
These values can usually be further optimized.
4-264
TNC 407/TNC 415/TNC 425
In "Manual operation" mode select the REF-
display with the MOD key.
Position-displays show the distance to the
machine datum .
Move all axes with the aid of the direction keys or
the handwheel in positive and negative direction to
values in the positional-displays and their sign.
Enter the noted values in MP910 or MP920.
Select actual-value display with MOD key.
Function
Analogue voltage for rapid
traverse
Acceleration
k v factor
Multiplication factor
Kink point
16 Commissioning and start-up procedure
provisional entry value
9 V
As measured on the machine
(see "Preparation of the machine")
1
1
max. mach. speed
Entry value =
·
100
%
Rapid traverse
01.98