Data Transfer Nc/Plc; Number Transfer - HEIDENHAIN TNC 415 Technical Manual

Hide thumbs Also See for TNC 415:
Table of Contents

Advertisement

Markers M1000 to M1999 and Bytes B0 to B127 are non-volatile, i.e. the contents of this memory
are maintained when the supply voltage is switched off.
After entry of the code number 531 210 the markers M1000 to M1999 and Bytes B0 to B127 are
erased.
B0 to B127
Freely available, not deleted with RESET
B128 to B255
Freely available, deleted with RESET
Data transfer NC → PLC
B256 to B511
Data transfer PLC → NC
B512 to B767
B768 to B1023
Machine parameters

2.3 Data transfer NC/PLC

The information exchange between PLC and NC is conducted by markers, Bytes, Words and
Doublewords. The function of the individual markers, Bytes, Words and Doublewords is fixed.
Either numerical data or general data (controlled by strobes) can be transferred.

2.3.1 Number transfer

The Parameter function FN19 can be used to transfer two numbers to the PLC. The transferred
values are deposited in the Doublewords D280 and D284.
During the transfer the marker M2149 is set by the NC. The transfer must be confirmed by the PLC
by setting marker M2611.
Marker M2150 determines whether dimensions are in mm or inches.
The transferred value is deposited as an integer number in units of 1/10 000.
Marker
M2149
M2611
M2150
Address
D 280
D 284
01.98
TNC 407/TNC 415/TNC 425
Function
Transfer with FN19 active
Confirm the transfer with FN19
Dimensional unit for transfer with FN19
0 = mm; 1 = inch
Function
1st Number value from FN 19
2nd Number value from FN 19
2 Program creation
Set
Reset
NC
NC
PLC
PLC
NC
NC
7-19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tnc 425eTnc 415fTnc 407Tnc 415bTnc 425

Table of Contents