MP3013.0 to
Characteristic kink points for analogue voltage output with M202
MP3013.11
Entry:
MP3014.0 to
Characteristic kink points for analogue voltage output with M202
MP3014.11
Entry:
Voltage varies with the time (time-voltage ramp): M203 V... TIME...
The TNC outputs the voltage as a function of the time. It increases or decreases the voltage linearly in
the time programmed behind TIME from the current voltage to the voltage value programmed behind
V...
Entry:
Voltage V:
TIME:
Duration:
M203 V... TIME... is effective until a new voltage is output through M200 to M204.
Voltage for a specific time (time pulse): M204 V... TIME...
The TNC outputs the voltage programmed behind V... as a pulse. The duration of the pulse is entered
with TIME....
Entry:
Voltage V:
TIME:
Duration:
M204 V... TIME... is effective until a new voltage is output through M200 to M204.
01.98
TNC 407/TNC 415/TNC 425
10 to 300 000 [mm/min]
0.000 to 9.999 [V]
0 to 9.999 [V]
0 to 1.999 [sec]
0 to 9.999 [V]
0 to 1.999 [sec]
17 Special functions for laser cutting machines