11.1.3 Analogue inputs
The PA 110, the PL 410 and the PL 410 B (Id.-Nr 263 371 02) have 4 analogue inputs (± 10 V) and 4
inputs for Pt 100 thermistors. These inputs must be activated by a DIL switch on the PL 410 /
PL 410 B and a machine parameter in the TNC. When the analogue inputs are active, two outputs
(O61/O62 or O93/O94 on PL #2) and eight inputs (I120 to I127 or I248 to I255 on PL #2) of the PLC
cannot be used. (See chapter "Machine integration", section "Analogue inputs").
11.1.4 Inputs for Pt 100 Thermistors
See chapter "Machine integration", section "Analogue inputs".
01.98
TNC 407/TNC 415/TNC 425
Voltage range
Input resistance
Resolution
Internal value range
Constant current
Temperature range
Resolution
Internal value range
11 PLC inputs/outputs
-10 V to +10 V
> 250 k Ω
100 mV
-100 to +100
5 mA
0°C to 100°C
0.5°C
0 to 200
3-53