2.4.2 Counters

32 counters are available in the PLC. Each of these 32 counters is controlled by special markers with
the abbreviation symbol C. After setting a marker from the range C0 to C31 the counter is loaded
with the value from machine parameter MP4120.X. The marker range C48 to C79 indicates whether
the count has been completed or not. The marker range C96 to C127 is used to start the counter
(counter release pulse).
Example:
Logic diagram for counter C1
Contents of machine parameter MP4120.1 = 10 (PLC cycles)
C1
C49
C97
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
C12
C13
C14
C15
C16
C17
C18
C19
C20
C21
C22
C23
C24
C25
C26
C27
C28
C29
C30
C31
7-26
TNC 407/TNC 415/TNC 425
C48
C49
C50
C51
C52
C53
C54
C55
C56
C57
C58
C59
C60
C61
C62
C63
C64
C65
C66
C67
C68
C69
C70
C71
C72
C73
C74
C75
C76
C77
C78
C79
2 Program creation
C96
C97
C98
C99
C100
C101
C102
C103
C104
C105
C106
C107
C108
C109
C110
C111
C112
C113
C114
C115
C116
C117
C118
C119
C120
C121
C122
C123
C124
C125
C126
C127
MP4120.0
MP4120.1
MP4120.2
MP4120.3
MP4120.4
MP4120.5
MP4120.6
MP4120.7
MP4120.8
MP4120.9
MP4120.10
MP4120.11
MP4120.12
MP4120.13
MP4120.14
MP4120.15
MP4120.16
MP4120.17
MP4120.18
MP4120.19
MP4120.20
MP4120.21
MP4120.22
MP4120.23
MP4120.24
MP4120.25
MP4120.26
MP4120.27
MP4120.28
MP4120.29
MP4120.30
MP4120.31