8 Key-simulation

The entry to the HEIDENHAIN contouring controls is by the keys on the TNC-keyboard (TE 400) and
the manufacturer's own machine-control panel. The two control panels are joined to connectors X45
and X46 on the logic-unit by a connecting cable (see "Assembly and electrical installation ").
The key-code from the TNC-keyboard is directly evaluated by the NC. PLC inputs and outputs for the
machine-control panel are available on connector X46 . These PLC inputs and outputs must be
evaluated by the PLC and the appropriate information passed to the NC.

8.1 TNC-keyboard (TE 400)

The key-code from the TNC-keyboard is directly evaluated by the NC.
The keys on the TNC-keyboard and the soft keys on the BC 110 B can be inhibited by the PLC. With
M2876 the entire alphabetic keyboard can be inhibited. M2877 inhibits the soft-key row and M2878
inhibits the changeover keys to the right of the screen. All other keys can be inhibited selectively
with M2854 to M2923. If an inhibited key is pressed, the NC sets the marker M2182 and deposits
the key-code for the key which was operated in word W274. The PLC must reset the marker
M2182 after evaluating this information.
The keys on the TNC-keyboard and the soft keys on screen can also be simulated by the PLC. To
achieve this the appropriate key-code is entered in Word W516 and activated by the strobe-marker
M2813. After execution of the key-code the NC resets the strobe-marker M2813.
A fixed code has been introduced for certain soft key functions. As with key simulation, this function
is executed by entering the required code in W516 and activating with M2813. The appropriate soft
key function must be displayed in the foreground or background mode for this. With the trailing edge
of M2813 the PLC is told whether the function was properly executed.
Address
Function
W272
Operating mode
1 = Manual operation
2 = Electronic handwheel
3 = Positioning with manual entry
4 = Program run/single block
5 = Program run/full sequence
7 = Pass over reference point
W274
Key-code for the operated, inhibited key,
Signal via M2182
W516
Word with multiple-function
Key-code for simulating TNC-key
activated by M2813
4-164
TNC 407/TNC 415/TNC 425
8 Key-simulation
Set
Reset
NC
NC
NC
NC
PLC
PLC