Greater Than Or Equal To - HEIDENHAIN TNC 415 Technical Manual

Hide thumbs Also See for TNC 415:
Table of Contents

Advertisement

3.5.5 GREATER THAN OR EQUAL TO (>=)
Abbreviation for PLC Editor:
Execution time [µs]
Number of bytes
Operands: B, W, D, K
Operation:
With this command, a direct transfer from Word to Logic execution occurs. The content of the Word
Accumulator is compared with the content of the addressed operand. If the Word Accumulator is
greater than or equal to the operand, the condition is true and the Logic Accumulator is set to 1. If
the Word Accumulator is smaller than the operand, the Logic Accumulator is set to 0. The
comparison takes place over the number of bits corresponding to the operand i.e. B=8 bit, W=16 bit
and D=K=32 bit.
Example:
A constant is to be compared with the content of Doubleword D8. The result is then assigned to
marker M500.
Initial state:
Accumulator and operand contents are entered here in decimal notation. The ten-position
Accumulator thus permits the maximum possible Accumulator content (2 147 483 647).
Line Instruction
1
L K16000
Bit
1
>= D8
2
= M500
Line 1: The constant is loaded into the Word Accumulator.
Line 2: The contents of the Word Accumulator and operand are compared according to the
following criteria: Word Accumulator >= Operand. As this condition is fulfilled, the Logic
Accumulator is set to 1.
Line 3: The content of the Logic Accumulator (result of the comparison) is assigned to marker
M500.
01.98
TNC 407/TNC 415/TNC 425
>= (GREATER EQUAL)
Byte/Word/Double
1.0 to 1.2
6
Constant
= 16 000
Doubleword D8 = 15 000
Accumulator Content
x
x x x
31
. . .
... x x x x x x 1 x x x x x x x
... x x x x x x 1 x x x x x x x
3 Commands
Constant
0.3 to 0.5
8
x x x
x x x
1 6
0 0 0
7
0
Operand Content
1 5
0 0 0
1
7-77

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tnc 425eTnc 415fTnc 407Tnc 415bTnc 425

Table of Contents