3.3.3 Offset adjustment with integral factor
The integral factor MP1080 also results in an automatic offset adjustment. It is only effective in the
stop condition (see block diagram of control loop).
According to the size of the factor the offset voltage will be reduced quickly or slowly.
Even a small amount of play in the drives can lead to instability in the control loop. An integral factor
of 0 is entered in this case.
Transformer
steps
(TNC 415:
0,15 mV)
10
8
6
4
2
MP1080
Integral factor
Entry: 0 to 65 535
MP1080.0
Integral factor X axis
MP1080.1
Integral factor Y axis
MP1080.2
Integral factor Z axis
MP1080.3
Integral factor 4th axis
MP1080.4
Integral factor 5th axis
4-78
TNC 407/TNC 415/TNC 425
MP1080 ·s
= 1000
a
1
2
3 Servo positioning of the NC-axes
MP1080 ·s
= 500
a
MP1080 ·s
3
4
= 150
a
t [s]
01.98