3.8 Setting the data interface

Machine
Function and input
parameter
MP5000
Inhibit data interface
Entry: 0 to 2
0 = Not inhibited
1 = RS-232-C/V.24 inhibited
2 = RS-422/V.11 inhibited
MP5020.0
Operating mode EXT 1
MP5020.1
Operating mode EXT 2
MP5020.2
Operating mode EXT 3 (PLC)
Entry: %xxxxxxx
Bit 0
7 or 8 Data bits
0 = 7 Data bits
1 = 8 Data bits
Bit 1
Block-Check-Character
0 = BCC-character optional
1 = BCC-character not Control character
Bit 2
Transmission stop through RTS
0 = not active
1 = active
Bit 3
Transmission stop through DC3
0 = not active
1 = active
Bit 4
Character parity
0 = even
1 = odd
Bit 5
Character parity
0 = not required
1 = required
Bit 6/7 Stop bits
1 1/2 Stop-Bits
2 Stop-Bits
1 Stop-Bit
1 Stop-Bit
MP5030.0
Operating mode EXT 1
MP5030.1
Operating mode EXT 2
MP5030.2
Operating mode EXT 3 (PLC)
Entry: 0 or 1
0 = "Standard data transmission"
1 = "Blockwise transfer"
5-26
TNC 407/TNC 415/TNC 425
Bit 6
Bit 7
Bit
0
Bit
0
Bit
1
Bit
0
Bit
0
Bit
1
Bit
1
Bit
1
3 List of machine parameters
Reaction
Change
via
PLC RUN
PLC RUN
CN 123
PLC RUN
CN 123
Page
8-21
8-24
8-24