3.7 Integral PLC

Machine
Function and input
parameter
MP4010
PLC-program from RAM or from EPROM
Entry: 0 or 1
0 = EPROM-operation
1 = RAM-operation
MP4060.0-4
Path dependent lubrication
Entry: 0 to 65 535
[units of 65 536 µm]
MP 4070
Compensation value per PLC cycle for axis error
compensation with lag tracking
Entry: 0.0001 to 0.005 [mm]
MP4110.0
Value for Timer T0 to T47
to
Entry: 0 to 65 535 [PLC-cycles]
MP4110.47
(TNC 415: 20 ms; TNC 407: 24 ms)
MP4120.0
Pre-set value for counters C0 to C31
to
Entry: 0 to 65 535 [PLC cycles]
MP4120. 31
MP4130
Fast PLC input to suppress the monitoring
functions
Entry: 0 to 255 [No. of the PLC input]
MP4131
Activation condition for fast PLC input from
MP4130
Entry: 0 or 1
MP4210.0
Set a number in the PLC (D768 to D956)
to
Entry: –99 999.9999 to +99 999.9999 [mm] or [°]
MP4210.47
MP4220.0-4
Machine parameter with multiple function
Entry: 10 to 30 000
Feed rate for returning to the contour
To set a number in the PLC in the word range
W960 to W968
MP4230.0
Set a number in the PLC (Module 9032)
to
Entry: –99 999.9999 to +99 999.9999
MP4230.31
MP4231.0
Set a number in the PLC (Module 9032)
to
Entry: –99 999.9999 to +99 999.9999
MP4231.31
MP4310.0-6
Set a number in the PLC ( W976 to W988)
Entry: 0 to 65 535
MP4410
Activation of analogue inputs
Entry: %xx
Bit 0 = 0 no analogue inputs on 1st extension
Bit 1 = 0 no analogue inputs on 2nd extension
01.98
TNC 407/TNC 415/TNC 425
1 analogue input on 1st extension
1 analogue input on 2nd extension
3 List of machine parameters
Reaction
Change
via
RESET
PLC RUN
PLC RUN
PLC RUN
PLC EDIT
PLC EDIT
PLC EDIT
PLC EDIT
PLC EDIT
PLC RUN
Page
7-28
4-19
4-32
7-25
7-26
4-83
4-83
7-21
4-148
7-23
7-23
7-23
7-22
7-178
4-206
5-25