Read-in file with acknowledgement

After commencement of transfer, the peripheral unit sends the first program module until the
receiving buffer of the TNC is full. The TNC then stops transmission with <DC3> and awaits
acknowledgement from the user. If the file is to be transferred, the TNC sends <DC1> and the
program is read in and stored. Otherwise the file is in fact read in but not stored. If hardware
handshaking is set, transfer by using the RTS signal is stopped and restarted.
Peripheral unit
1st line of file 1 <CR> <LF>
2nd line of file 1 <CR> <LF>
Last line of file 1 <CR> <LF> <ETX>
Last line of last file <CR> <LF> <ETX>
01.98
TNC 407/TNC 415/TNC 425
<NUL> <NUL>
.
.
.
.
.
.
<NUL>
.
.
.
<ETX>
2 TNC data interfaces
Transmission path
.
.
.
.
.
.
TNC
<DC1>
<DC3> Polling:
Read in
<DC1>
Yes / No
<DC1>
<DC1>
<EOT>