6.4 Status-window

The status of the control (axis positions, tools, feed, M-functions etc.) is displayed on the VDU-screen in
the status window. A Soft key can be used to activate an additional status-display in the graphics
window instead of the graphics.
The colours for the status-window display can be altered by machine parameters.

6.4.1 Position display

The input resolutions for the TNCs are:
– TNC 415 B: 0.0001 mm or 0.0001°
– TNC 415 F and TNC 407: 0.001 mm or 0.001°
The display-step for the axis positions can be selected for specific axes by machine parameter.
Regardless of this selection the TNC always attempts to position precisely to 0.0001 mm or 0.0001°
(regardless of the grating period of the measuring system and the smallest voltage increment).
The most recently selected axis is displayed inversely. The PLC is informed (by a marker) which axis
has an inverse display. This information can be evaluated, for example, in connection with hand-
control equipment.
Machine parameter MP7285 can be used to select whether, in the positional-display, the tool axis
takes account of the tool length or not.
MP7285
Calculation of the tool length in the position-display of the tool axis
Entry: 0 or 1
0 = tool length ignored
1 = tool length taken into account
MP7290
Position-display step
Entry: 0 to 6
0 = 0.1 mm or 0.1°
1 = 0.05 mm or 0.05°
2 = 0.01 mm or 0.01°
3 = 0.005 mm or 0.005°
4 = 0.001 mm or 0.001°
5 = 0.0005 mm or 0.0005°
6 = 0.0001 mm or 0.0001°
The following input values apply for software types 259 96 (TNC 415 A) and 243 02 (TNC 407):
0 = 0.001 mm or 0.001°
1 = 0.005 mm or 0.005°
2 = 0.0001 mm or 0.0001°
4-134