8.2.2 TS 511

The TS 511 touch probe system can only function together with a transmitter/receiver unit (SE 510)
and interface electronics (APE 510).
3 m
SE 510
SE 510
WH
0V
BN
U
P
GY
Flash signal
GN
IR-signal
Internal
WH/
screen (0V)
BK
The signals may be inverted by changing the switch positions S1 to S4 in the APE 510.
See operating instructions TS 511.
Please install the transmitter/receiver unit SE 510 either insulated from, or electrically connected to
the machine, as it must take up a definite potential, also under vibration. The earthing screw of
the APE 510 must be joined to the machine signal ground by a potential compensating lead
(≥ ∅ 6 mm²). See also under the heading "Earthing plan".
3-38
TNC 407/TNC 415/TNC 425
max. 7 m
Id.-Nr. 274 540 ..
GY
1
1
YL
2
2
RD
BN
3
3
WH
4
4
GN
5
5
BL
6
6
7
7
WH/
BK
8 Touch probe system input
max. 30 m
Id.-Nr. 274 539 ..
APE 510
1
7
GY
APE
2
5
510
YL
3
3
BN
4
2
5
6
BL
6
1
WH
7
4
GN
X12
Touch probe input
WH/BN
1
1
Internal screen (0V)
2
2
3
3
Standby
4
4
Start
15V ±10% (U
5
5
P
6
6
7
7
Battery warning
8
8
0V (U
)
N
9
9
10
10
Trigger signal
11
11
12
12
13
13
14
14
15
15