Reference Pulse Inhibit Input - HEIDENHAIN TNC 415 Technical Manual

Hide thumbs Also See for TNC 415:
Table of Contents

Advertisement

7 Reference pulse inhibit input

The reference pulse inhibit input can be used to suppress the evaluation of the reference pulse input
of each of the six measuring systems. This is achieved by simply applying a positive potential (13 V
to +30.3 V) to the appropriate reference pulse inhibit input. Pin 9 of the female connector X10
(reference pulse inhibit) must be connected to 0 V of the PLC-power supply.
The reference pulse inhibit inputs are only available in the LE 415 A. These inputs are
normally unused. See also Chapter "Machine Integration".
7.1 Connector assignment
X10 Reference pulse inhibit (LE 415 A only)
Flange socket with female connector insert (9-pin)
Pin number
Assignment
1
Screen
2
Reference pulse inhibit input X1
3
Reference pulse inhibit input X2
4
Reference pulse inhibit input X3
5
Reference pulse inhibit input X4
6
Reference pulse inhibit input X5
7
Reference pulse inhibit input X6
8
Do not use
9
0 V (PLC)
7.2 Connecting cable
Standard commercially available screened cables can be used for the connections to the reference
pulse inhibit inputs.
HEIDENHAIN can deliver a 9-pin D-subminiature connector (Id.-Nr. 244 503 ZY) for this purpose.
01.98
TNC 407/TNC 415/TNC 425
X10
7 Reference pulse inhibit input
3-35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tnc 425eTnc 415fTnc 407Tnc 415bTnc 425