Check nominal position
LN
M2011
AN
M300
A
M305
A
M5
CMT
370
L
M4
A
M5
AN
M2011
S
M3018
Activate Hirth module
LN
M2011
A
M301
A
M302
A
M305
S
M300
L
M300
AN
M3018
CMT
300
EM
LBL
290
RPLY
B128
<>
K + 0
EMT
SUBM
291
=
B128
EM
LBL
291
PS
K + 420
PS
K + 3
CM
9032
PLW
<>
K + 0
=
M301
L
M1
S
M304
L
M1
S
M2719
S
M2495
S
M2547
EM
LBL
292
RPLY
B128
<>
K + 0
EMT
SUBM
293
=
B128
EM
4-214
TNC 407/TNC 415/TNC 425
;axis 4 not in position
;nominal value in grid spacing?
;1 = not in grid
;controlled mode
;axis 4 not in position
;error message "Nominal position not attainable
in controlled mode"
;axis 4 not in position
;Hirth status 1 = activated
;switch-on delay terminated
;set marker for memory
;reset by subprogram 300
;nominal position not attainable in controlled mode
Hirth positioning
;interrogate Submit
;read MP420.3
;MP420
;Index 3
;value 1/10 000
;1 = active, 0 = not active
;Submit 1 ready
;M1 = 1
;start word memory processing
;open activation control loop, axis 4
;open control loop, axis 4
;interrogate Submit
;Job identifier
13 Hirth coupling
01.98