3.5.3 Monitoring the analogue voltage

Monitoring of the analogue voltage is only possible in operation with feedforward control.
If it exceeds 10 V, the flashing error message
"Gross positioning error B"
is displayed.

3.5.4 Movement-monitoring

The movement-monitoring functions in operation with feedforward control as well as with lag.
During movement monitoring, the actual path travelled is compared with a nominal path calculated
by the NC at short intervals (several servo cycles). If, during this period, the actual path travelled
differs from the calculated path, the flashing error message
"Gross positioning error C"
is displayed.
In machine parameter MP1140 a voltage can be stored, below which the movement-monitoring is
out of action.
If 10 [V] is entered in this machine parameter, the movement-monitoring becomes
inactive. It is not possible to operate the machine safely without movement
monitoring.
MP1140
Movement monitoring
Entry: 0.030 to 10.000 (V)
MP1140.0
Axis X
MP1140.1
Axis Y
MP1140.2
Axis Z
MP1140.3
4th axis
MP1140.4
5th axis
4-86
TNC 407/TNC 415/TNC 425
3 Servo positioning of the NC-axes
01.98