16.3.9 Adjust the offset

The rough offset-adjustment has already been carried out on the servo-amplifier. A fine offset-
adjustment can be performed with the offset-adjustment possibility described in the section "Servo
positioning".

16.3.10 Adjustment of the monitoring functions

The following entry values are recommended for the monitoring functions (see section "Servo
positioning"):
Machine parameter
MP1710
MP1720
MP1410
MP1420
MP1140
MP1030
MP1110
If the drives of the machine permit narrower limits, these may be entered.
01.98
TNC 407/TNC 415/TNC 425
Function
Position monitoring
Position monitoring (EMERGENCY STOP)
Position monitoring
Position monitoring (EMERGENCY STOP)
Movement monitoring
Positioning window
Standstill monitoring
16 Commissioning and start-up procedure
Entry value
1.2 × lag in rapid traverse
1.4 × lag in rapid traverse
0.5 [mm]
10 [mm]
0.5 [V]
0.01 [mm]
0.2 [mm]