MP340
Interpolation factor of the EXE at X5, X6 (only TNC 407)
Input: 0, 1, 5
0 = No encoder at X5, X6
1 = EXE without Interpolation
5 = EXE with 5-fold interpolation
MP340.0
X axis
MP340.1
Y axis
MP340.2
Z axis
MP340.3
4th axis
MP340.4
5th axis

1.1.2 Direction of traverse

The machine parameters MP210 and MP1040 determine the direction of traverse for the axes. The
direction of traverse for the axes of numerically controlled machine tools are defined by DIN (see
also under Sections "Axis designation" and "Commissioning and start-up procedure").
MP210 defines the counting direction for the measuring system signals. The counting direction
depends on the mounting orientation of the measuring systems.
MP210
Counting direction of the measuring system signals
Entry: %xxxxx
Bit 0
X axis
Bit 1
Y axis
Bit 2
Z axis
Bit 3
4th axis
Bit 4
5th axis
Machine parameter MP1040 determines the polarity of the nominal value voltage during the positive
direction of traverse.
MP1040
Polarity of the nominal value voltage for the positive direction of traverse
Entry: %xxxxx
Bit 0
X axis
Bit 1
Y axis
Bit 2
Z axis
Bit 3
4th axis
Bit 4
5th axis
4-8
TNC 407/TNC 415/TNC 425
or EXE without interpolation
0 = positive
1 = negative
0 = positive
1 = negative
1 Machine axes