Gear Range - HEIDENHAIN TNC 415 Technical Manual

Hide thumbs Also See for TNC 415:
Table of Contents

Advertisement

MP3140
Count direction of the measuring system signals for the spindle
0 =positive count direction with M03
1 =negative count direction with M03
Marker
Function
M2489
Change direction of spindle rotation
M2485
Status display and output of the analogue voltage
for M03
M2486
Status display and output of the analogue voltage
for M04
M2487
Status display M05 and spindle-stop
M2608
Inverse display of M03, M04, M05 and
S-analogue = 0 V [no spindle-enable)

4.1.2 Gear range

With the aid of the machine parameters MP3510 and MP3210 up to eight gear ranges can be
defined. The nominal speed for S-override 100 % and a matching S-analogue voltage is entered for
each gear range.
If not all gear ranges are required, then the remaining machine parameters are set to zero.
Machine parameter MP3515 can be used to define a maximum achievable spindle speed for each
gear range which cannot be exceeded by S-override.
The voltage range can be restricted by machine parameter MP3240.1.
MP3120 can determine whether zero spindle speed is permitted, in spite of a minimum producable
analogue output voltage.
If an S-analogue voltage output 0 V is produced, marker M2005 will be set. This is also the case
when the potential has been turned down to zero with the override potentiometer.
The ramp slope for the S-analogue voltage on output of M03, M04 is stored in MP3410.0.
If the spindle voltage is on a rising or falling ramp, marker M2004 will be set. This also happens
when the spindle voltage is altered with the override potentiometer, the voltage changes very
quickly, and the ramp of MP3410.0 cannot be followed.
4-96
TNC 407/TNC 415/TNC 425
4 Main Spindle
Set
Reset
PLC
PLC
PLC
PLC
PLC
PLC
PLC
PLC
PLC
PLC
01.98

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tnc 425eTnc 415fTnc 407Tnc 415bTnc 425

Table of Contents