Calculation of possible oscillations in normal direction
optimised F
MP 6210 [1/s] =
PP.INT
When the calculated machine parameter MP 6210 is entered the feed override potentiometer is
trimmed to the "attained feed rate".
1)
Maximum possible feed rate noted during optimizing
2)
PP.INT is the programmed maximum probe point interval from the "Meander" scanning
cycle (in the example, PP.INT = 1 mm).
4-188
TNC 407/TNC 415/TNC 425
1)
[mm / min]
2)
[mm] x 60 [s / min]
9 Touch probe
01.98