The NC uses markers to tell the PLC in which direction the axes are travelling.
Marker
Function
M2160
Direction of
to M2164
traverse
0 = positive
1 = negative
M2160
X axis
M2161
Y axis
M2162
Z axis
M2163
4th axis
M2164
5th axis

1.1.3 Measuring system monitoring

HEIDENHAIN contouring controls can monitor the signal transmissions of the measuring system.
This measuring system monitoring must be activated by a machine parameter.
Three different conditions can be checked:
The absolute position of distance-coded reference marks
The amplitude of the measuring system signals
The edge separation of the measuring system signals
If one of the conditions is not fulfilled, the error message "Measuring system <axis> defective
A/B/C" will appear.
For sinusoidal signals the LE monitors the amplitude of the measuring system signals, for square-
wave signals the LE evaluates the fault detection signal (U
MP30
Checking the absolute position of the distance-coded reference marks
Entry: %xxxxx
Bit 0
X axis
Bit 1
Y axis
Bit 2
Z axis
Bit 3
4th axis
Bit 4
5th axis
01.98
TNC 407/TNC 415/TNC 425
Set
Reset
NC
NC
0 = not active
1 = active
1 Machine axes
Error message
C
A
B
) of the external electronics (EXE).