End of Indexed Module Call (ENDC)

Abbreviation for PLC Editor:
Execution time [µs]
Number of bytes
Operands: none
Operation:
The ENDC command is used together with the CASE command. It must come directly after the list
of CM commands.
Structure of a CASE instruction:
Internal addressing (0 to 127 max.)
1
CASE B 150
2
CM 100
<-------
3
CM 200
<-------
4
CM 201
<-------
5
CM 202
<-------
6
CM 203
<-------
7
CM 204
<-------
8
CM 300
<-------
9
ENDC
Line 1: Command + Operand; the internal address of the required module must be filed in the
operand
Line 2: Call Module if operand content 0
Line 3: Call Module if operand content 1
Line 4: Call Module if operand content 2
Line 5: Call Module if operand content 3
Line 6: Call Module if operand content 4
Line 7: Call Module if operand content 5
Line 8: Call Module if operand content 6
Line 9: End of CASE instruction
7-130
TNC 407/TNC 415/TNC 425
ENDC (ENDCASE)
Byte
Word
0
0
(0)
(1)
(2)
(3)
(4)
(5)
(6)
3 Commands