Pulse Output / PWM Output Function
9.1.4 Configuration Using Tool Software
The setting of the pulse output/PWM output function is specified in the configuration menu of
FPWIN GR7.
Setting method
The following procedure describes the process when the multi I/O unit has been already
allocated in the I/O map.
PROCEDURE
1. Select "Options" > "Multi I/O Unit Setting" in the menu bar.
The "Mufti I/O Unit Setting" dialog box will be displayed. Select a unit to be used.
2. Select "Pulse output" from the "Selection of function" tree, and double-click
an output number to which the pulse output/PWM output is allocated.
The "Pulse output Advanced" dialog box will be displayed.
3. Select a function setting, data update timing, and input a frequency.
When selecting PWM output, set a duty ratio. Set the upper and lower limit values
of the counter for the pulse output/PWM output according to applications.
4. Select a pulse start logic.
Select either "OFF start" or "ON start".
9-4