The parameters for JOG operations are specified in the positioning parameter setting menus
of Configuration PMX.
 Settings
Item
Startup speed
JOG acceleration time
Axis setting area
JOG deceleration time
JOG target speed
 Configurator PMX Paramter settings screen
 Allocation of I/O signals
Signal name
JOG+
JOG-
 Sample program
The execution condition is set to be always executed.
R0
R1
R0
R1
Value
1,000 Hz
100 ms
200 ms
20,000 Hz
Application
JOG operation start
(Forward)
JOG operation start
(Reverse)
I/O number
Axis 1
Axis 2
CH0
CH1
Y3C
Y3D
Y40
Y41
Y3C
CH No.0
Start JOG forward operation.
Y40
CH No.0
Start JOG reverse operation.
10.8 JOG Operation
Axis 3
Axis 4
CH2
CH3
Y3E
Y3F
Y42
Y43