Panasonic FP7 User Manual page 237

Multi input/output unit
Hide thumbs Also See for FP7:
Table of Contents

Advertisement

Unit
memory
Name
no.
(Hex)
Starting table
UM 00209
number (CH0)
Starting table
UM 0020A
number (CH1)
Starting table
UM 0020B
number (CH2)
Starting table
UM 0020C
number (CH3)
UM 0020D
Reserved for system
-UM 0020F
Simultaneous
UM 00210
starting table number
(CH0)
Simultaneous
UM 00211
starting table number
(CH1)
Simultaneous
UM 00212
starting table number
(CH2)
Simultaneous
UM 00213
starting table number
(CH3)
UM 00214
Reserved for system
-UM 002D
13.5 Unit Memory Detailed Information (H type)
Default
Description
U0
Specify the table number to be started when a
U0
positioning start signal is input.
Setting value: 1 to 20
U0
When setting 0, the table number is 1.
U0
-
-
U0
Specify the table number to be started when a
positioning simultaneous start signal is input.
U0
Setting value: 0
Specified channels do not start simultaneously.
U0
Setting value: 1 to 20
Specified channels start with the set table number.
U0
-
-
A: Available, -: Not available
R
W
A
A
A
A
A
A
A
A
-
-
A
A
A
A
A
A
A
A
-
-
13-45