Settings And Operations Of Repeat Operation - Panasonic FP7 User Manual

Multi input/output unit
Hide thumbs Also See for FP7:
Table of Contents

Advertisement

10.11.2

Settings and Operations of Repeat Operation

• When the positioning table start contact or positioning simultaneous start contact turns on,
the pulse output starts.
• After starting the instruction, the unit executes the pulse output for a specified repeat count
and then stops the operation. For setting to execute the operation infinitely, use this function
in combination with the deceleration stop function.
 Operation diagram
 Operations of each contact
• The BUSY flags (X30-X33), which indicate that the motor is running, will turn on when the
position control starts, and they will turn off when the set repeat operation completes.
• The operation done flags (X34-X37), which indicate the completion of operation, will turn on
when the current operation is completed, and they will be held until the next positioning
control, JOG operation or home return operation starts. Those flags do not turn off in the
middle of the repeat operation.
10.11 Repeat Operation
10-63