Mitsubishi Electric MELSEC-Q Series User Manual page 348

Cc-link system master/local module
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

Number
Name
Forced master
SB005C
switching request
(5E5
, b12)
H
acknowledgement
Forced master
SB005D
switching request
(5E5
, b13)
H
complete
Execution status of
SB005E
remote device station
(5E5
, b14)
initialization
H
procedure
Completion status of
SB005F
remote device station
(5E5
, b15)
initialization
H
procedure
SB0060
Host mode
(5E6
, b0)
H
SB0061
Host type
(5E6
, b1)
H
Host standby master
SB0062
station setting
(5E6
, b2)
H
information
Input data status of
SB0065
host data link faulty
(5E6
, b5)
H
station
SB0066
(5E6
, b6)
H
Number of host
occupied stations
SB0067
(5E6
, b7)
H
SB006A
Switch setting status
(5E6
, b10)
H
346
Description
Whether a forced master switching request has been
accepted is stored.
OFF: Not accepted
ON: Accepted
Whether a forced master switching request has been
completed is stored.
OFF: Not completed
ON: Completed
Whether the initialization procedure is being performed is
stored.
OFF: Not performed
ON: In process
Whether the initialization procedure has been completed
is stored.
OFF: Not completed
ON: Completed
The setting status of the transmission speed/mode setting
switch on the host station is stored.
OFF: Online
ON: Mode other than online
The station type of the host station is stored.
OFF: Master station (station number: 0)
ON: Local station (station number: 1 to 64)
Whether the host station has been set as a standby
master station is stored.
OFF: Not set
ON: Set
The status of the data link faulty station setting configured
for the host station is stored.
OFF: Clear
ON: Hold
The number of occupied stations of the host station is
stored.
Number of
occupied
SB0066
stations
1
OFF
2
OFF
3
ON
4
ON
Whether the switch has been correctly set is stored.
OFF: Correct
ON: Setting incorrect (An error code is stored in
SW006A.)
Availability
( : Yes, ×: No)
Online
Master
station
(Standby
master
station only)
(Standby
master
station only)
SB0067
×
OFF
ON
ON
OFF
Offline
Local
station
×
×
(Standby
×
master
station
only)
×
×
×
×
×
×
×

Hide quick links: