Mitsubishi Electric MELSEC-Q Series User Manual page 335

Cc-link system master/local module
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

(3) Remote register (RWw) and remote register (RWr)
This area is used when the remote net Ver.1 mode or remote net additional mode is selected.
• In the remote net Ver.1 mode, data are stored in the remote register (RWr/RWw). (
3.6.3 (3))
• In the remote net additional mode, data are stored in the remote register (RWr/RWw) in a Ver.1-compatible
slave station. (
(a) Remote register (RWr)
Buffer
Station
Station
memory
number
number
address
2E0
to 2E3
H
H
1
14
(736 to 739)
2E4
to 2E7
H
H
2
15
(740 to 743)
2E8
to 2EB
H
H
3
16
(744 to 747)
2EC
to 2EF
H
H
4
17
(748 to 751)
2F0
to 2F3
H
H
5
18
(752 to 755)
2F4
to 2F7
H
H
6
19
(756 to 759)
2F8
to 2FB
H
H
7
20
(760 to 763)
2FC
to 2FF
H
H
8
21
(764 to 767)
300
to 303
H
H
9
22
(768 to 771)
304
to 307
H
H
10
23
(772 to 775)
308
to 30B
H
H
11
24
(776 to 779)
30C
to 30F
H
H
12
25
(780 to 783)
310
to 313
H
H
13
26
(784 to 787)
Page 54, Section 3.6.5 (3))
Buffer
Buffer
Station
memory
memory
number
address
address
314
to 317
348
H
H
H
27
(788 to 791)
(840 to 843)
318
to 31B
34C
H
H
H
28
(792 to 795)
(844 to 847)
31C
to 31F
350
H
H
H
29
(796 to 799)
(848 to 851)
320
to 323
354
H
H
H
30
(800 to 803)
(852 to 855)
324
to 327
358
H
H
H
31
(804 to 807)
(856 to 859)
328
to 32B
35C
H
H
H
32
(808 to 811)
(860 to 863)
32C
to 32F
360
H
H
H
33
(812 to 815)
(864 to 867)
330
to 333
364
H
H
H
34
(816 to 819)
(868 to 871)
334
to 337
368
H
H
H
35
(820 to 823)
(872 to 875)
338
to 33B
36C
H
H
H
36
(824 to 827)
(876 to 879)
33C
to 33F
370
H
H
H
37
(828 to 831)
(880 to 883)
340
to 343
374
H
H
H
38
(832 to 835)
(884 to 887)
344
to 347
378
H
H
H
39
(836 to 839)
(888 to 891)
Buffer
Station
memory
number
address
to 34B
37C
to 37F
H
H
40
(892 to 895)
to 34F
380
to 383
H
H
41
(896 to 899)
to 353
384
to 387
H
H
42
(900 to 903)
to 357
388
to 38B
H
H
43
(904 to 907)
to 35B
38C
to 38F
H
H
44
(908 to 911)
to 35F
390
to 393
H
H
45
(912 to 915)
to 363
394
to 397
H
H
46
(916 to 919)
to 367
398
to 39B
H
H
47
(920 to 923)
to 36B
39C
to 39F
H
H
48
(924 to 927)
to 36F
3A0
to 3A3
H
H
49
(928 to 931)
to 373
3A4
to 3A7
H
H
50
(932 to 935)
to 377
3A8
to 3AB
H
H
51
(936 to 939)
to 37B
3AC
to 3AF
H
H
52
(940 to 943)
APPENDICES
Page 47, Section
Buffer
Station
memory
number
address
3B0
to 3B3
H
H
H
53
(944 to 947)
3B4
to 3B7
H
H
H
54
(948 to 951)
3B8
to 3BB
H
H
H
55
(952 to 955)
3BC
to 3BF
H
H
H
56
(956 to 959)
3C0
to 3C3
H
H
H
57
(960 to 963)
3C4
to 3C7
H
H
H
58
(964 to 967)
3C8
to 3CB
H
H
H
59
(968 to 971)
3CC
to 3CF
H
H
H
60
(972 to 975)
3D0
to 3D3
H
H
H
61
(976 to 979)
3D4
to 3D7
H
H
H
62
(980 to 983)
3D8
to 3DB
H
H
H
63
(984 to 987)
3DC
to 3DF
H
H
H
64
(988 to 991)
H
333
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents