Mitsubishi Electric MELSEC-Q Series User Manual page 62

Cc-link system master/local module
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

2.
Plan the device assignment.
The status of a device assignment can be checked on GX Works2 by setting information of a slave station on the CC-Link
configuration window on GX Works2. (
[View]
• Remote input (RX)
Plan the assignment using the assignment sheet on Page 407, Appendix 8.1 (1).
CPU module
Device
X1000 to X100F
X1010 to X101F
*1
X1020 to X102F
X103 to X103F
*1
In the AJ65BTB1-16DT, the first eight points are used for input, and the last eight points are used for output. RX0 to RX7
are used for input in the AJ65BTB1-16DT. In a CPU module, X1020 to X1027 are actually used.
CPU module
Device
X1000
Station
No.1
X101F
X1020
X1027
X1028
Station
No.2
X103F
60
[Docking Window]
Master station
Buffer memory address
Hexadecimal
Decimal
E0
224
H
E1
225
H
E2
226
H
E3
227
H
Remote I/O station
Master station
(output 16 points)
Buffer memory
(Remote input (RX))
E0
(224)
H
Station
No.1
E1
(225)
H
E2
(226)
H
Station
No.2
E3
(227)
H
Page 102, Section 7.3.2 (2) (a))
[Device Reference]
Station number
1
2
AJ65BTB2-16T
AJ65BTB1-16DT
output module
combined module
Remote I/O station
(input 8 points, output 8 points)
Station No.1
Station No.2
Remote input (RX)
Station
No.2
Slave station
Module name
Remote I/O (RX/RY)
AJ65BTB2-16T
RX0 to RXF
AJ65BTB1-16DT
RX0
RX7
Device actually used by
the remote I/O station
to
to
*1
to