Mitsubishi Electric MELSEC-Q Series User Manual page 354

Cc-link system master/local module
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

Number
Name
Dedicated
SW000B
instruction retry
(60B
)
H
count setting
SW0014
(614
)
H
SW0015
Specification of
(615
)
H
remote device
station to be
SW0016
initialized
(616
)
H
SW0017
(617
)
H
SW0020
Module status
(620
)
H
SW0041
Data link restart
(641
)
result
H
Refresh
SW0043
instruction at
(643
)
standby master
H
switching result
SW0045
Data link stop
(645
)
result
H
Temporary error
SW0049
invalid station
(649
)
specification
H
result
Temporary error
SW004B
invalid station
(64B
)
specification
H
cancel result
SW004D
Line test result
(64D
)
H
352
Set the number of retries of when dedicated instructions are used.
Default: 0 (No retry)
Range: 0 to 7 (time)
If a value outside the range is set, the number of times will be 7.
Specify a station where an initial process is performed using the
information registered by the initialization procedure registration using a
programming tool.
0: Initial process not performed
1: Initial process performed
b15
b14
b13
SW0014
16
15
14
SW0015
32
31
30
SW0016
48
47
46
SW0017
64
63
62
1 to 64 in the table indicate station numbers.
The stations need not be set by the number of occupied stations.
Error invalid stations, reserved stations, station with the last station
number, and stations later than that are excepted.
The status of communications between the master/local module and
CPU module is stored.
0: Normal completion
Values other than 0: Error code of the CPU module (
manual for the CPU module used)
Whether the data link restart instruction using SB0000 has been normally
completed is stored.
0: Normal completion
Values other than 0: Error code (
Whether the refresh instruction at standby master switching has been
normally completed is stored.
0: Normal completion
Values other than 0: Error code (
Whether the data link stop instruction using SB0002 has been normally
completed is stored.
0: Normal completion
Values other than 0: Error code (
Whether the temporary error invalid station specification has been
normally completed is stored.
0: Normal completion
Values other than 0: Error code (
Whether the temporary error invalid station setting has been normally
canceled is stored.
0: Normal completion
Values other than 0: Error code (
The result of a line test is stored.
0: Normal
Values other than 0: Error code (
Description
b12
to
b3
b2
b1
13
to
4
3
29
to
20
19
18
45
to
36
35
34
61
to
52
51
50
Page 293, Section 11.3.2)
Page 293, Section 11.3.2)
Page 293, Section 11.3.2)
Page 293, Section 11.3.2)
Page 293, Section 11.3.2)
Page 293, Section 11.3.2)
Availability
( : Yes, ×: No)
Online
Master
station
station
b0
2
1
17
33
49
User's
Offline
Local
×
×
×
×
×
×
×
×
×
×
×
×
×

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents