General AUSM Provisioning Procedures
Configuring the Master Side of SPVCs
To configure the master side of an SPVC, perform the following steps:
Step 1
Establish a configuration session using a user name with GROUP1 privileges or higher.
During this procedure, you will have to enter the ATM address for the slave end of the connection. If you
Tip
establish this session from the same workstation you used to create the slave connection, you can do a
copy and paste sequence to avoid data entry errors.
Step 2
To define the master side of the SPVC connection, enter the following command:
PXM1E_SJ.VHSHS2B.a > addcon <port_number> <vpi> <vci> [-ct <ConnectionType>]
[-contp <ControllerType>] [-st
[-rmc <RemoteConnId>] [-abrtype <ABRType>] [-abrpcr
[-osub <OvrSubFlag>] [-ipcu <IngrPercentUtil>] [-epcu <EgrPercentUtil>]
[-upce <UpcEnable>] [-scrp <SCRPolicing>] [-ccdv <CDVT[0+1]>] [-cte <CLPTagEnable>]
[-dis <DiscardOption>] [-pcr01 <IngrUpcPCR[0+1]>] [-scr <IngrUpcSCR>]
[-cbs <MaxBurstSize>] [-maxcost <MaxCost>] [-rtngpri <RoutingPriority>]
[-type <restrictedType>] [-rpcr <RemotePCR>] [-rscr <RemoteSCR>] [-rmcr <RemoteMCR>]
[-rcbs <RemoteMaxBurstSize>]
If the addcon command fails and displays the "Failed to update disk" message, it could be that the PNNI
Note
controller has not been added on the PXM1E card. For information on adding the PNNI controller, refer
to the Cisco MGX 8850 (PXM1E) and MGX 883Cisco MGX 8850 (PXM1E) and MGX 8830 Software
Configuration Guide, Release 3.
Table 2-7
Tip
If you omit one or more of the options when entering the addcon command, the connection uses the
default values listed in
the desired value. Any parameters you enter must match the corresponding parameters defined for the
slave end of the connection.
The following addcon command defines a port as the master side of a double-ended SPVC.
PXM1E_SJ.1.4.AUSMB8.a > addcon 2 100 100 -master 1 -rmc
4700918100000000016444445c00000101230100.100.100
To view the master-side of the new SPVC connection in the connection list, enter the dspcons command:
Step 3
PXM1E_SJ.1.4.AUSMB8.a > dspcons
LCN
---- ---- --- ----- -------
0016 001
0017 002
Number of channels:
ChanNumNextAvailable
Local VpId NextAvailable :
This command displays all the connections for the AUSM card.
Cisco AUSM Software Configuration Guide and Command Reference for MGX 8850 (PXM1E) and MGX 8830
2-22
lists and describes the parameters for the addcon command.
Table
2-7. To override the default value for a given option, enter the option with
Port VPI
VCI
Class
100 00100 CBR1
100 00100 CBR1
2
:
<ServiceClassTtype>] [-master
Type
M/S EgrQ Admin Alarm
----- --- ---- ----- -----
VCC
S
1
Up
PORT-ALARM
VCC
M
1
Up
PORT-ALARM
18
1
Release 3, Part Number 78-14254-01 Rev. A0, October 2002
Chapter 2
Provisioning Communications Links
<MasterShip>]