Show Logging Application - Enterasys SecureStack B3 Configuration Manual

Stackable switches
Table of Contents

Advertisement

show logging application

Parameters
facility 
severity 
port
Defaults
At least one optional parameter must be entered.
All three optional keywords must be entered to reset all logging values to defaults.
Mode
Switch command, read‐write.
Example
This example shows how to reset the Syslog default severity level to 6:
B3(su)->clear logging default severity
show logging application
Use this command to display the severity level of Syslog messages for one or all applications 
configured for logging on your system.
Syntax
show logging application [mnemonic | all]
Parameters
mnemonic
all
Defaults
If no parameter is specified, information for all applications will be displayed.
Mode
Switch command, read‐only.
13-6 Logging and Network Management
(Optional) Resets the default facility name to local4.
(Optional) Resets the default logging severity level to 6 (notifications of 
significant conditions).
(Optional) Resets the default UDP port the client uses to send to the server 
to 514.
(Optional) Displays severity level for one application configured for 
logging. Mnemonics will vary depending on the number and types of 
applications running on your system. Sample mnemonics and their 
corresponding applications are listed in Table
Note: Mnemonic values are case sensitive and must be typed as they appear in
Table 13-3.
(Optional) Displays severity level for all applications configured for 
logging.
13‐3 on page 13‐8.

Advertisement

Table of Contents
loading

Table of Contents