Clear Port Mirroring; Set Mirror Vlan - Enterasys SecureStack B3 Configuration Manual

Stackable switches
Table of Contents

Advertisement

clear port mirroring

Defaults
None.
Mode
Switch command, read‐write.
Usage
Note that LAG ports and their underlying physical ports, as described in "Link Aggregation 
Control Protocol (LACP)" on page 5‐34, cannot be mirrored.
Example
This example shows how to create and enable port mirroring with 
.1.11 as the target port:
ge
B3(su)->set port mirroring create ge.1.4 ge.1.11
B3(su)->set port mirroring enable ge.1.4 ge.1.11
clear port mirroring
Use this command to clear a port mirroring relationship. 
Syntax
clear port mirroring source destination
Parameters
source
destination
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to clear port mirroring between source port 
.1.11:
ge
B3(su)->clear port mirroring ge.1.4 ge.1.11

set mirror vlan

Assigns a VLAN to be reserved for mirroring traffic. If a mirrored VLAN is created, all mirrored 
traffic will egress VLAN tagged. All traffic on the mirror VLAN will be flooded.
Syntax
set mirror vlan vlan-id
5-32 Port Configuration
Specifies the source port of the mirroring configuration to be cleared. For 
a detailed description of possible port‐string values, refer to "Port String 
Syntax Used in the CLI" on page 5‐1.
Specifies the target port of the mirroring configuration to be cleared. 
.1.4 as the source port, and 
ge
.1.4 and target port 
ge

Advertisement

Table of Contents
loading