clear logging default

Defaults
None.
Mode
Switch command, read-write, if security profile = normal.
Switch command, super-user, if security profile = c2
Example
This example shows how to set the Syslog default facility name to local2 and the severity level to 4
(error logging):
C3(su)->set logging default facility local2 severity 4
clear logging default
Use this command to reset logging default values.
Syntax
clear logging default {[facility] [severity] [port]}
Parameters
facility
severity
port
Defaults
At least one optional parameter must be entered.
All three optional keywords must be entered to reset all logging values to defaults.
Mode
Switch command, read-write, if security profile = normal.
Switch command, super-user, if security profile = c2
Example
This example shows how to reset the Syslog default severity level to 3:
C3(su)->clear logging default severity

show logging application

Use this command to display the severity level of Syslog messages for one or all applications
configured for logging on your system.
Syntax
show logging application [mnemonic | all]
(Optional) Resets the default facility name to local4.
(Optional) Resets the default logging severity level to 3 (critical).
(Optional) Resets the default UDP port the client uses to send to the server
to 514.
Configuring System Logging
Enterasys C3 Configuration Guide 19-7